Model: T2-RMSC20/30/40/50/60 | 30A | 40A | 50A | 60A | 80A | 100A |
Charging Mode | MPPT Automatic Maximum Power Point Tracking |
Charging Method | Three stages: Constant Current (MPPT), Balanced Charging, Floating Charge |
System Type | 12/24/36/48(V) | Automatic Identification/Manual Setting |
System Identification Voltage Range | 12V System | DC9V-DC15V |
24V System | DC18V-DC30V |
36V System | DC27V-DC45V |
48V System | DC36V-DC60V |
Soft Start Time | 12/24/36/48(V) | 10s |
Dynamic Response Recovery Time | 12/24/36/48(V) | 500us |
Static Power | 12/24/36/48(V) | 2W |
Machine Efficiency | 12/24/36/48(V) | 96.5% |
PV Module Utilization | 12/24/36/48(V) | 99.97% |
MPPT Operating Voltage Range | 12V System | DC18V-DC150V |
24V System | DC34V-DC150V |
36V System | DC48V-DC150V |
48V System | DC65V-DC150V |
Input Low Voltage Protection Point | 12V System | DC16V |
24V System | DC30V |
36V System | DC45V |
48V System | DC60V |
Input Low Voltage Recovery Point | 12V System | DC18V |
24V System | DC34V |
36V System | DC48V |
48V System | DC65V |
Limit Input Voltage | 12/24/36/48(V) | DC160V |
Overvoltage Protection | 12/24/36/48(V) | DC150V |
Overvoltage Recovery | 12/24/36/48(V) | DC145V |
Optional Battery Type (Default is lead-acid main te nance- free battery) | 12/24/36/48(V) | Lead-acid maintenance-free Battery, Gel Battery, Liquid Battery, Lithium Battery (Can also be customized for other types of battery) |
Floating Charge Voltage (Lead Acid Battery) | 12V System | 13.75V(Can be customized) |
24V System | 27.50V(Can be customized) |
36V System | 41.25V(Can be customized) |
48V System | 55.00V(Can be customized) |
Average charging Voltage (Lead Acid Battery) | 12V System | 14.20V(Can be customized) |
24V System | 28.40V(Can be customized) |
36V System | 42.60V(Can be customized) |
48V System | 56.80V(Can be customized) |
Temperature Coefficient | 12V/24V/36V/48V | 0.02%/ |
Temperature Compensation | 12V/24V/36V/48V | 14.2V-(Maximum Temperature -25C)*0.3 |
Output Regulation Accuracy | 1.5% |
LCD Display | Details in LCD Display Instruction |
LED Display | Charging Indication, DC Output Switch Status Indication |
PC Host Computer | Rs485(Optional) |
Protection |
Input Low Voltage Protection | Reference Input Characteristics |
Input High Voltage Protection | Reference Input Characteristics |
Input Polarity Reverse Connection Protection | Available |
Output Polarity Reverse Connection Protection | Available |
Short Circuit Protection | After 5 trial starts will enter the protection state, Restart Recovery |
Temperature Protection | 85 |
Temperature Rise Protection | Reduce Power Output When Exceed 80 |
Heat Dissipation Method | Forced air cooling, the fan speed is adjusted by temperature, when the internal temperature is low, the fan runs slowly or stops; when the controller stops working, the fan will stop running |
Element | Imported Materials, in line with EU standards, all-temperature selection of electrolytic capacitors rated temperature is not less than 105 |
Smell | Do not release the peculiar smell and harmful health smell |
Environmental Requirements | Conform 2002/95/EC; No Cadmium, Hydride, and Fluoride |